In a randomized scientific trial, SCOPE II, a brand new self-expanding bioprosthetic valve utilized in transcatheter aortic valve alternative (TAVR) did not display non-inferiority in comparison with an current self-expanding valve.

Findings have been reported at present at TCT Join, the 32nd annual scientific symposium of the Cardiovascular Analysis Basis (CRF). TCT is the world’s premier instructional assembly specializing in interventional cardiovascular drugs. The research was additionally revealed concurrently in Circulation.

The SCOPE II trial was designed to check the scientific outcomes of the ACURATE neo and CoreValve Evolut valves. A complete of 796 sufferers aged 75 years or older with symptomatic extreme aortic stenosis and a sign for transfemoral TAVR as agreed by the Coronary heart Workforce have been recruited at 23 tertiary coronary heart valves facilities in Denmark, France, Germany, Italy, Spain and the UK. Contributors have been randomly assigned (1:1) to obtain remedy with the ACURATE neo (n=398) or the CoreValve Evolut gadgets (n=398).

The first security endpoint, powered for non-inferiority of the ACURATE neo valve utilizing a noninferiority margin of 6%, was the composite of all-cause mortality or stroke at 12 months. The first efficacy endpoint, powered for superiority, was new everlasting pacemaker implantation at 30 days. Secondary endpoints included scientific efficacy and security endpoints at 30 days and 12 months.

Within the intention-to-treat evaluation, demise or stroke at one yr was 15.8% within the ACURATE neo group in comparison with 13.9% within the CoreValve Evolut group, whereas within the per-protocol evaluation it was 15.3% vs. 14.3%.

Noninferiority of the ACURATE neo was not met for the first endpoint within the intent-to-treat evaluation, whereas it was met within the per-protocol evaluation. Based mostly on the prespecified statistical plan, resulting from these inconsistent outcomes, non-inferiority was not established for the first endpoint.

New pacemaker implantation at 30 days was 10.5% with ACURATE neo in comparison with 18.0% with CoreValve Evolut (Threat Distinction -7.5%, 95% CI -12.4–2.60, P= 0.0027). Cardiac demise at 30 days (2.8% vs 0.8%, p=0.03) and one yr (8.4% vs 3.9%, p=0.01) was better within the ACURATE neo group. The speed of moderate-severe aortic regurgitation was 9.6% vs 2.9% (P<0.0001) at 30 days and 4.0% vs. 3.3% (P<0.0001) at one yr.

TAVR with the ACURATE neo valve didn’t meet noninferiority in contrast with the CoreValve Evolut bioprosthesis with respect to a composite of demise or stroke at one yr. In a secondary evaluation with restricted statistical energy, cardiac demise was elevated at one yr in sufferers who acquired the ACURATE neo valve. The 2 valves additionally differed with respect to technical traits corresponding to diploma of aortic regurgitation and wish for brand new everlasting pacemaker implantation.”


Corrado Tamburino, MD, PhD, Division of Cardiology, Policlinico – College of Catania